Technical Support Pages

 

Title
I get an error code 52 "Cannot Open Volume Pipe" when starting a backup/verify/restore.
Keywords
error 52 backupedge 01.02.0x 02.00.0x 02.01.0x 02.02.0x edgemenu edge.nightly Cannot Open Volume Pipe
Product Release(s)
02.02.0x 02.01.0x 02.00.0x 01.02.0x
Operating System(s)
All Supported
Problem Description
When starting a backup / verify / restore operation, I get an error code 52 almost immediately.
Cause
Error 52 idicates that edgemenu or edge.nightly could not communicate with the volume switching subsystem.

Usually the log file /usr/lib/edge/lists/LogFile will contain additional information.

Solution
Make sure that the directories /usr/lib/edge/system/tmp /usr/lib/edge/system/locks and /usr/lib/edge/system/pipes exist. If any of these are missing, you may get an error 52.